Be sure this information reaches the operator.
You can get extra copies through your supplier.
INSTRUCTION MANUAL
PCM-750i
PLASMA ARC CUTTING PACKAGE
Series A
This manual provides installation and operation instructions for the following PCM-750i (Series A) cutting packages:
P/N 33980 - 230 V, 1-Phase
P/N 33982 - 460 V, 3-Phase
Starting with Serial No. PORI509000
F-15-223-A
February, 1996
These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principles of operation and
safe practices for electric welding equipment, we urge you to read our booklet, "Precautions and Safe Practices for
Arc Welding, Cutting, and Gouging," Form 52-529. Do NOT permit untrained persons to install, operate, or maintain
this equipment. Do NOT attempt to install or operate this equipment until you have read and fully understand these
instructions. If you do not fully understand these instructions, contact your supplier for further information. Be sure
to read the Safety Precautions before installing or operating this equipment.
Vedere la pagina 0
1 2 3 4 5 6 ... 35 36

Sommario

Pagina 1 - PLASMA ARC CUTTING PACKAGE

Be sure this information reaches the operator.You can get extra copies through your supplier.INSTRUCTION MANUALPCM-750iPLASMA ARC CUTTING PACKAGESerie

Pagina 2 - TABLE OF CONTENTS

SECTION 2 INSTALLATION102.1 GENERALProper installation can contribute materially to the satis-factory and trouble-free operation of the PCM-750i c

Pagina 3 - SAFETY PRECAUTIONS

SECTION 2 INSTALLATION11Figure 2-1. PCM-750i Interconnection DiagramCUSTOMER PROVIDEDAIR SUPPLY(150 psig MAX;90 psig MIN)NO. 8 CU/AWG 3-CONDUC-TOR

Pagina 4 - §25249.5 et seq.)

SECTION 2 INSTALLATION12Figure 2-2. Ground and Work Cable ConnectionsDO NOT ATTACH WORKCABLE TO PIECE BEING CUTFREEWORK CABLEEARTH GROUNDGROUNDEDWO

Pagina 5 - PRÉCAUTIONS DE SÉCURITÉ

SECTION 3 OPERATION13E. Fault Light. Will glow red under the followingconditions and operations will come to a completestop:1. When duty cycle

Pagina 6

SECTION 3 OPERATION14NOTEWhen replacing the nozzle, always inspect the elec-trode for wear. If less than 11/16" of electrode shaft isremai

Pagina 7 - SECTION 1 DESCRIPTION

SECTION 3 OPERATION153.4 COMMON CUTTING PROBLEMSListed below are common cutting problems followed bythe probable cause of each. If problems ar

Pagina 8

SECTION 4 MAINTENANCE164.1 GENERALIf this equipment does not operate properly, stop workimmediately and investigate the cause of the malfunc-tion.

Pagina 9

SECTION 4 MAINTENANCE174.4 FLOW SWITCH (FIGURE 4-2)When excessive contamination is found in the air, theflow switch (FS-4 or FS-5) should be disas

Pagina 10 - SECTION 2 INSTALLATION

SECTION 5 TROUBLESHOOTING18The cause of control malfunctions can be found byreferring to the sequence of operations and electricalschematic diagram (

Pagina 11

SECTION 5 TROUBLESHOOTING19B. No AirIs air hose connected?Yes No ConnectIs air adjusted to 65 psig?Yes No AdjustDoes air come on with air ch

Pagina 12

USER RESPONSIBILITYThis equipment will perform in conformity with the description thereof contained in this manual and accompanyinglabels and/or inser

Pagina 13 - SECTION 3 OPERATION

SECTION 5 TROUBLESHOOTING20C. Air does not shut offIs air check switch OFF?Yes No Turn switch OFFDoes arc start when nozzle contacts work without dep

Pagina 14 - SECTION 3 OPERATION

SECTION 5 TROUBLESHOOTING21D. Green "Power" light not energized.Is main 230 volt switch ON?Yes No Turn on main disconnectIs plug i

Pagina 15

SECTION 5 TROUBLESHOOTING22E. Red "FAULT" light ON.Is the unit overheated?("Fault" lights turns offwhen Unit cools down.)Yes NoIs

Pagina 16 - SECTION 4 MAINTENANCE

SECTION 5 TROUBLESHOOTING23TORCH SWITCHOPEN CLOSEGAS SOLENOID VALVEPREFLOWFLOW SWITCH CLOSEFAULT OVERLOAD LIGHTHF CIRCUITINVERTERCU

Pagina 17

SECTION 5 TROUBLESHOOTING2410 SEC PUSH RELEASE PUSH RELEASE TORCH SWITCH OPEN CLOSE GAS SOLENOID VALVEPOSTFLOW CLOSE OPEN

Pagina 18 - SECTION 5 TROUBLESHOOTING

25Figure 5-1. PCM-750i (Series A) Schematic Diagram (460 V, 3-Phase Input)D-35511-A

Pagina 19

26Figure 5-2. PCM-750i (Series A) Wiring Diagram (460 V, 3-Phase Input)D-35510-A

Pagina 20

27Figure 5-3. PCM-750i (Series A) Schematic Diagram (230 V, 1-Phase Input)D-35507-A

Pagina 21

28Figure 5-4. PCM-750i (Series A) Wiring Diagram (230 V, 1-Phase Input)D-35506-A

Pagina 22

SECTION 6 REPLACEMENT PARTS29Replacement parts may be ordered from your ESABdistributor or from:ESAB Welding & Cutting ProductsAttn: Custome

Pagina 23 - 5.3 Sequence of Operation

3WARNING: These Safety Precautions are foryour protection. They summarize precaution-ary information from the references listed inAdditional Safety In

Pagina 24

SECTION 6 REPLACEMENT PARTS3012A13,1415171813,428ITEMNO.QTYREQ.PARTNO.DESCRIPTIONCIRCUITSYMBOL12345678910111213141516171811111111111111111111339

Pagina 25 - D-35511-A

SECTION 6 REPLACEMENT PARTS31VIEW A-A2,17134REF 5FIGURE 6-65616151479,810111213REF 12FIGURE 6-1Figure 6-2. PCM-750i (Series A) Power Source (Rig

Pagina 26 - D-35510-A

SECTION 6 REPLACEMENT PARTS32VIEW A-A2,19134REF 5FIGURE 6-65616151479,810111213REF 12FIGURE 6-1Figure 6-3. PCM-750i (Series A) Power Source (Rig

Pagina 27 - D-35507-A

SECTION 6 REPLACEMENT PARTS3313124,35678REF 4FIGURE 6-691114 (PCB2)17182114 (PCB3)16152019104,32012ITEMNO.QTYREQ.PARTNO.DESCRIPTIONCIRCUITSYMBOL

Pagina 28 - D-35506-A

SECTION 6 REPLACEMENT PARTS341314124,35678REF 4FIGURE 6-691011121617Figure 6-5. PCM-750i (Series A) Power Source (Left Side View)P/N 33982 - 460

Pagina 29 - 6.2 ORDERING

SECTION 6 REPLACEMENT PARTS351897112345610Figure 6-6. PCM-750i (Series A) Power Source (Rear View)ITEMNO.QTYREQ.PARTNO.DESCRIPTIONCIRCUITSYMBOL1

Pagina 30

F-15-223-A 2/96 4M Printed in U.S.A.IF YOU DO NOT KNOW WHOM TO CALLTelephone: (800) ESAB-123Hours: 7:30 AM to 5:00 PM ESTESAB Welding & Cutting

Pagina 31

4FUMES AND GASES -- Fumes andgases, can cause discomfort or harm,particularly in confined spaces. Donot breathe fumes and gases. Shield-ing gases can

Pagina 32

5a. Éloigner suffisamment tous les matériaux combus-tibles du secteur où l’on exécute des soudures ou descoupes à l’arc, à moins de les recouvrir com

Pagina 33

6pas sage d’un courant de sortie par des chaînesdelevage des câbles de grue ou divers cheminsélectriques.g. Empêchez l’apparition de toute humidité, n

Pagina 34

SECTION 1 DESCRIPTION71.1 GENERALThe PCM-750i is a compact, completely self-containedplasma cutting system. As shipped, the system is fullyassem

Pagina 35

SECTION 1 DESCRIPTION81.4 SPECIFICATIONSRefer to Tables 1-3, 1-4, and Figures 1-1 and 1-2 forPCM-750i technical specifications.Table 1-3. PCM-75

Pagina 36

SECTION 1 DESCRIPTION9Table 1-4. PT-27 Torch Specifications 1" (25.4 mm) 3" (76 mm) 1"(25.4 mm) 7.3" (185 mm)75°Figure